Capacitor & Reactance Calculator

Calculate capacitive reactance (Xc), stored energy (Joules), and series/parallel capacitor network values.

Hz
V

Capacitive Reactance & Energy

Capacitive Reactance (Xc)
265.258 Ω

Opposition to AC current at 60 Hz

Stored Electrostatic Energy (E)
0.072 Joules (72.000 mJ)

@ 120 V applied

Step-by-Step Engineering Calculation

  1. 1Angular Frequency: ω=2π×60 Hz=376.99 rad/s\omega = 2\pi \times 60\text{ Hz} = 376.99\text{ rad/s}ω=2π×60 Hz=376.99 rad/s
  2. 2Reactance Formula: XC=\ rac12π imesf imesCX_C = \ rac{1}{2\pi \ imes f \ imes C}XC​=\ rac12π imesf imesC
  3. 3Capacitive Reactance: XC=12π×60×1.0000e−5=265.2582 ΩX_C = \frac{1}{2\pi \times 60 \times 1.0000e-5} = \mathbf{265.2582\ \Omega}XC​=2π×60×1.0000e−51​=265.2582 Ω
  4. 4Stored Energy: E=12×C×V2=12×1.0000e−5 F×(120 V)2=0.072000 JE = \frac{1}{2} \times C \times V^2 = \frac{1}{2} \times 1.0000e-5\text{ F} \times (120\text{ V})^2 = \mathbf{0.072000\text{ J}}E=21​×C×V2=21​×1.0000e−5 F×(120 V)2=0.072000 J (72.000 mJ)

Formula & Theory

X_C = 1 / (2π × f × C) | E = ½ × C × V²

Computes AC opposition to current (reactance in Ohms) and electrostatic stored potential energy in Joules.

Variable Definitions
X_C:
Reactance (Ohms (Ω)) – Opposition to AC current flow
f:
Frequency (Hertz (Hz)) – AC signal frequency
C:
Capacitance (Farads (F / µF / nF / pF)) – Electrical capacitance
E:
Stored Energy (Joules (J)) – Electrostatic energy stored in electric field

Worked Engineering Example

10µF Filter Capacitor at 60Hz

A 10µF capacitor operating in a 120V 60Hz AC filter circuit.

Inputs:
  • Frequency: 60 Hz
  • Capacitance: 10 µF
  • Voltage: 120 V
Result: Reactance Xc = 265.26 Ω | Stored Energy = 0.072 J (72 mJ)

Key Assumptions

  • •Sinusoidal AC waveform.

Limitations & Safety Scope

  • •Does not include dielectric loss (Equivalent Series Resistance, ESR).
VoltBase Pro (voltbase.pro) • Electrical Engineering Reference & Calculation Submittal
Governing Reference: NEC 2023 / IEEE Standard Baseline
Calculated By: __________________________
Reviewed By: __________________________
Approved / Stamped: __________________________

Frequently Asked Questions

Why does capacitive reactance decrease as frequency increases?

As frequency rises, the capacitor charges and discharges more frequently per second, allowing more charge to move per unit time, which reduces the effective opposition (reactance) to AC current.

Related Calculators & Engineering Tools

Power Factor Calculator
Ohm's Law Calculator

Educational & Reference Notice: This calculator provides technical estimates based on standard physical formulas. Actual electrical installation, protective device sizing, and conductor selection must be verified against the applicable electrical code (NEC, IEC, CEC) by a licensed electrician or qualified professional engineer.

VoltBasePRO

Fast, practical electrical calculators, conversions, engineering charts, and technical reference tools.

Free Engineering Utilities

Calculators

  • Ohm's Law
  • Voltage Drop
  • Wire Sizing
  • Battery Runtime
  • Solar Array Sizing
  • Breaker Sizing
  • View All 20+ →

Converters & Charts

  • AWG to mm²
  • Watts to Amps
  • kW to HP
  • AWG Wire Table
  • Battery SoC Chart
  • Resistor Color Code

Reference & Guides

  • All Articles & Guides →
  • Master Formulas
  • Grounding vs Bonding
  • 3-Phase Motor Sizing
  • Transformer Sizing
  • Conduit Fill Guide
  • Unit Converter Tool

Platform & Standards

  • About VoltBase Pro
  • Editorial Guidelines
  • Calculation Methodology
  • Engineering Disclaimer
  • Contact & Peer Review
  • Privacy Policy
  • Terms of Use
  • HTML Sitemap

Engineering Disclaimer: Calculations, estimations, formulas, and charts provided on VoltBase Pro are intended solely for educational, reference, and informational purposes. Real-world electrical installations must comply with local electrical codes (e.g. NEC, IEC, CEC) and should always be verified by a licensed electrician or professional electrical engineer.

© 2026 VoltBase Pro. All rights reserved.

Calculated in your browser. Verified against NEC 2023 tables.