Voltage Drop Calculator

Calculate voltage drop, percentage loss, and remaining load voltage for DC, single-phase, and 3-phase circuits over distance.

Calculates AC Effective Impedance (Z) with conduit reactance per NEC Ch. 9 Table 9.

V
A

Typical: 0.85 motors, 0.95 lighting, 1.0 resistive

Voltage Drop Analysis

Voltage Drop (ΔV)
5.185 V (4.32%)

⚠ Acceptable for total feeder + branch circuit (≤ 5%)

Voltage at Load Terminal
114.81 V

From 120V supply under 15A load

Power Dissipated in Conductors
90 W

Conductor thermal I²R energy loss

Effective Loop Impedance (Z)
0.34569 Ω

Includes conduit magnetic reactance

Voltage Drop Advisory
Voltage drop exceeds 3% NEC branch circuit guideline. Consider upsizing wire gauge or running parallel sets.

Step-by-Step Engineering Calculation

  1. 1Method: NEC Chapter 9 Table 9 (AC Effective Impedance at 75°C, 60Hz)
  2. 2Conduit: STEEL Raceway | Conductor: COPPER 12 AWG
  3. 3Code Resistance: R=2 Ω/kftR = 2\ \Omega/\text{kft}R=2 Ω/kft | Reactance: XL=0.054 Ω/kftX_L = 0.054\ \Omega/\text{kft}XL​=0.054 Ω/kft
  4. 4Power Factor: PF=cos⁡θ=0.85\text{PF} = \cos\theta = 0.85PF=cosθ=0.85 (sin⁡θ=0.5268\sin\theta = 0.5268sinθ=0.5268)
  5. 5Effective Impedance: Zeff=(2×0.85)+(0.054×0.5268)=1.7284 Ω/kftZ_{\text{eff}} = (2 \times 0.85) + (0.054 \times 0.5268) = \mathbf{1.7284\ \Omega/\text{kft}}Zeff​=(2×0.85)+(0.054×0.5268)=1.7284 Ω/kft
  6. 6Circuit Length: L=100.0 ftL = 100.0\text{ ft}L=100.0 ft (30.5 m) | Parallel sets: 1
  7. 7Voltage Drop: ΔV=2×15 A×1.7284 Ω/kft×100.0 ft1000×1=5.185 V\Delta V = 2 \times 15\text{ A} \times \frac{1.7284\ \Omega/\text{kft} \times 100.0\text{ ft}}{1000 \times 1} = \mathbf{5.185\text{ V}}ΔV=2×15 A×1000×11.7284 Ω/kft×100.0 ft​=5.185 V
  8. 8Voltage Drop Percentage: 5.185 V120 V×100=4.32%\frac{5.185\text{ V}}{120\text{ V}} \times 100 = \mathbf{4.32\%}120 V5.185 V​×100=4.32%
  9. 9Voltage at Terminal Load: Vload=120 V−5.185 V=114.815 VV_{\text{load}} = 120\text{ V} - 5.185\text{ V} = \mathbf{114.815\text{ V}}Vload​=120 V−5.185 V=114.815 V
  10. 10Total Conductor Thermal Power Loss: Ploss=90.00 WP_{\text{loss}} = \mathbf{90.00\text{ W}}Ploss​=90.00 W

Formula & Theory

ΔV_1φ = 2 × I × (ρ × L / A) | ΔV_3φ = √3 × I × (ρ × L / A)

Calculates the voltage reduction along a conductor run caused by the internal electrical resistance of copper or aluminum wiring.

Variable Definitions
ΔV:
Voltage Drop (Volts (V)) – Voltage lost across the conductor run
%ΔV:
Voltage Drop % (Percentage (%)) – Proportion of source voltage lost
L:
One-Way Length (Meters / Feet) – Distance between power source and load
ρ:
Resistivity (Ω·m) – Conductor resistivity at operating temperature

Worked Engineering Example

100-Foot 120V Branch Circuit

A 120V 15A load powered over 100 feet of 12 AWG copper wire at 20°C.

Inputs:
  • Voltage: 120 V
  • Current: 15 A
  • Length: 100 ft
  • Wire: 12 AWG Copper
Result: Voltage Drop = 4.76 V (3.97%), Load Voltage = 115.24 V

Key Assumptions

  • •Conductor resistance is calculated at specified temperature (standard 20°C / 75°C).
  • •Power factor is assumed to be 1.0 (purely resistive) for DC and basic AC calculations.

Limitations & Safety Scope

  • •Inductive cable reactance (X_L) becomes significant in large conductors (> 4/0 AWG) or steel conduit runs and should be factored in for large commercial feeders.
  • •Does not guarantee regulatory electrical code compliance. Always verify with applicable local codes (NEC, IEC, CEC).
VoltBase Pro (voltbase.pro) • Electrical Engineering Reference & Calculation Submittal
Governing Reference: NEC 2023 / IEEE Standard Baseline
Calculated By: __________________________
Reviewed By: __________________________
Approved / Stamped: __________________________

Frequently Asked Questions

What is the maximum allowable voltage drop under the NEC?

The NEC recommends a maximum 3% voltage drop on branch circuits and 5% total voltage drop combined across feeder and branch circuits for optimal efficiency.

Why does copper have less voltage drop than aluminum?

Copper has a lower electrical resistivity (1.724 × 10⁻⁸ Ω·m) compared to aluminum (2.82 × 10⁻⁸ Ω·m), meaning an aluminum conductor must have roughly 61% greater cross-sectional area to match the resistance of copper.

Related Calculators & Engineering Tools

Wire Size Calculator
AWG to mm² Converter
Breaker Size Calculator
Voltage Drop Basics Reference
Wire Sizing Engineering Principles
How to Calculate Voltage Drop

Educational & Reference Notice: This calculator provides technical estimates based on standard physical formulas. Actual electrical installation, protective device sizing, and conductor selection must be verified against the applicable electrical code (NEC, IEC, CEC) by a licensed electrician or qualified professional engineer.

VoltBasePRO

Fast, practical electrical calculators, conversions, engineering charts, and technical reference tools.

Free Engineering Utilities

Calculators

  • Ohm's Law
  • Voltage Drop
  • Wire Sizing
  • Battery Runtime
  • Solar Array Sizing
  • Breaker Sizing
  • View All 20+ →

Converters & Charts

  • AWG to mm²
  • Watts to Amps
  • kW to HP
  • AWG Wire Table
  • Battery SoC Chart
  • Resistor Color Code

Reference & Guides

  • All Articles & Guides →
  • Master Formulas
  • Grounding vs Bonding
  • 3-Phase Motor Sizing
  • Transformer Sizing
  • Conduit Fill Guide
  • Unit Converter Tool

Platform & Standards

  • About VoltBase Pro
  • Editorial Guidelines
  • Calculation Methodology
  • Engineering Disclaimer
  • Contact & Peer Review
  • Privacy Policy
  • Terms of Use
  • HTML Sitemap

Engineering Disclaimer: Calculations, estimations, formulas, and charts provided on VoltBase Pro are intended solely for educational, reference, and informational purposes. Real-world electrical installations must comply with local electrical codes (e.g. NEC, IEC, CEC) and should always be verified by a licensed electrician or professional electrical engineer.

© 2026 VoltBase Pro. All rights reserved.

Calculated in your browser. Verified against NEC 2023 tables.