Unit ConverterInstant Bidirectional Conversion

Watt Hours to Amp Hours Converter (Wh to Ah)

Convert energy in watt-hours back to battery capacity in amp-hours for a 12V, 24V or 48V bank. Essential when a load is rated in Wh or kWh.

Convert Watt-Hours to Amp-Hours

Wh

Conversion Result

Capacity in Amp-Hours (Ah)
100 Ah

At 12 V nominal battery voltage

Battery Size to Buy for 50% DoD (Lead-Acid)
200 Ah

Lead-acid banks are sized at twice the usable capacity needed

Battery Size to Buy for 80% DoD (LiFePO4)
125 Ah

LiFePO4 banks can use 80% of their rated capacity

Step-by-Step Engineering Calculation

  1. 1Charge capacity: Ah=1200 Wh12 V=100.00 Ah\text{Ah} = \frac{1200\text{ Wh}}{12\text{ V}} = \mathbf{100.00\text{ Ah}}
  2. 2Use the battery's nominal voltage (12 V, 24 V, 48 V), not its fully charged voltage, so the rating matches how manufacturers label capacity.

Conversion Formula & Relationship

Ah = Wh / V

Dividing stored or consumed energy by the battery's nominal voltage gives the charge capacity in amp-hours, the unit batteries are sold and labeled in.

Standard Conversion Example

Input: 2,560 Wh at 12 V
Result: 213.3 Ah

A 2,560 Wh power station rating equals 2,560 / 12 = 213.3 Ah at 12 V nominal. The same energy at 48 V would need only 53.3 Ah.

2,560 Wh at 12 V = 213.3 Ah

Quick Reference Conversion Table

Watt-Hours (Wh)Amp-Hours (Ah)Common Application / Context
600 Wh @ 12V50 AhSmall power station
1,200 Wh @ 12V100 AhOne deep-cycle battery
2,400 Wh @ 24V100 AhOff-grid cabin bank
5,120 Wh @ 48V106.7 AhStandard 5.12 kWh wall battery
10,240 Wh @ 48V213.3 AhWhole-home backup

Frequently Asked Questions

A power station says 768 Wh. How many Ah is that?

Divide by the voltage you are comparing at. At 12 V it is 64 Ah. Note the power station's internal battery may run at a different voltage, so Wh is the honest figure for comparing energy across products.

Should I size my battery bank from Wh or Ah?

Start from energy: add up the watt-hours your loads consume per day, then convert to Ah at your system voltage and add margin for depth of discharge and inverter losses.